Product Details
Place of Origin: China
Brand Name: NetTAP®
Certification: CCC, CE, RoHS
Model Number: NT-FBYP-L1G
Payment & Shipping Terms
Minimum Order Quantity: 1 SET
Price: Can Discuss
Packaging Details: Outer Carton plus Inner Foam
Delivery Time: 1-3 Working Days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100 sets per month
Inline Bypass: |
Deploy With, Anti-DDoS |
BYPASS Detection: |
Intelligent Heartbeat Technology |
Network Monitor: |
Monitoring Tools Depend On Heartbeat Package |
Reliable Data Access: |
Up/down Link Heartbeat Package Respond |
Applications:: |
Data Center Physical Connection Protection |
Heartbeat Packet Detection: |
VLAN Tag, L3 And L4 Custom Message |
Inline Bypass: |
Deploy With, Anti-DDoS |
BYPASS Detection: |
Intelligent Heartbeat Technology |
Network Monitor: |
Monitoring Tools Depend On Heartbeat Package |
Reliable Data Access: |
Up/down Link Heartbeat Package Respond |
Applications:: |
Data Center Physical Connection Protection |
Heartbeat Packet Detection: |
VLAN Tag, L3 And L4 Custom Message |
Inline Bypass Network TAP Detect Heartbeat Message Respond for Anti DDos Protector
1. Anti DDos Protector Bypass TAP Intelligent Heartbeat Message Detection Technology
Define Heartbeat Messages
The heartbeat packets of the NetTAP® policy traction protector default to Ethernet Layer 2 frames. When deploying transparent Layer 2 bridging mode (such as IPS / FW), Layer 2 Ethernet frames are normally forwarded,blocked or discarded. At the same time, NetTAP® policy traction protector also supports custom heartbeat message format to meet the situation that some special serial security devices can not normally forward ordinary Layer 2 Ethernet frames.
The NetTAP® Policy Traction Protector also supports heartbeat packet detection based on VLAN tag, Layer 3 and Layer 4 custom message types. Based on this mechanism, the user can implement a service safety test function of the connection safety device to make it more effective to ensure that the corresponding security services work properly.
NetTAP® "Strategic Traffic Traction Protector" can also support the monitor to send different heartbeat packets in both directions. For example, TCP and UDP type heartbeat packets are customized on the "Strategy Traffic Traction Protector", according to the particularity of the serial device. You can configure the sending of TCP heartbeat packets on the uplink monitor A port and the sending of UDP heartbeat packets on the downlink monitor B port to accommodate the message forwarding mechanism of the serial security device. This function can more effectively guarantee the string. Connect the safety equipment to normal operation.
2. Intelligent Anti DDos Protector Application Solution
Based on the dynamic strategy of traffic traction security detection protection
"Bypass Switch" Another advanced application scenario is based on the dynamic strategy of traffic traction security detection protection applications, the deployment of the way as shown below:
Take the "anti-DDoS attack protection and detection" security testing equipment, for example, through the front-end deployment of "bypass switch" and then anti-DDOS protection equipment and then connected to the "bypass switch", in the usual " Traction protector "to the full amount of traffic wire-speed forwarding at the same time the flow mirror output to the" anti-DDOS attack protection device ", once detected for a server IP (or IP network segment) after the attack," anti-DDOS attack protection device " will generate the target traffic flow matching rules and send them to the "bypass switch" through the dynamic policy delivery interface. The "bypass switch" can update the "traffic traction dynamic" after receiving the dynamic policy rules Rule pool "and immediately" rule hit the attack server traffic "traction to the" anti-DDoS attack protection and detection "equipment for processing, to be effective after the attack flow and then re-injected into the network.
The application scheme based on the "bypass switch" is easier to implement than the traditional BGP route injection or other traffic traction scheme, and the environment is less dependent on the network and the reliability is higher.
"Bypass Switch" has the following characteristics to support dynamic policy security detection protection:
1,"bypass switch" to provide outside the rules based on WEBSERIVCE interface, easy integration with third-party security devices.
2,"bypass switch" based on the hardware pure ASIC chip forwarding up to 10Gbps wire-speed packets without blocking switch forwarding, and "traffic traction dynamic rule library" regardless of the number.
3,"policy flow traction protector" built-in professional BYPASS function, even if the protector itself failure, can also bypass the original serial link immediately, does not affect the original link of normal communication.
3. Anti DDos Protector Bypass TAP Technical Specifications
Product model | Specifications |
NT-FBYP-L1X-SR | 1U chassis, 1*10GE multimode optical protection link |
NT-FBYP-L1X-LR | 1U chassis, 1*10GE single-mode optical protection link |
NT-FBYP-L1G-SX | 1U chassis, 1*GE multi-mode optical protection link |
NT-FBYP-L1G-LX | 1U chassis, 1*GE single mode optical protection link |
NT-CBYP-L1G | 1U chassis, 1*GE electrical protection link |
NT-CBYP-L2G | 1U chassis, 2*GE electrical protection link |
NT-FBYP-L2G-SX5 | 1U chassis, 2*GE multi-mode optical protection link |
NT-FBYP-L2G-LX | 1U chassis, 2*GE single-mode optical protection link |
NT-FCBYP-L4XG-SR | 1U chassis, 2*GE electrical protection link, 1*GE multi-mode optical protection link, 1*10GE multimode optical protection link |
NT-FCBYP-L4XG-LR | 1U chassis, 2*GE electrical protection link, 1*GE single mode optical protection link, 1*10GE single mode optical protection link |
2*GE Optical BYPASS Links(NT-FBYP-L2G)
Product Model | NT-FBYP-L2G | |
Interface form | SFP slot | 4 * SFP slot, support 1000BASE-LX / SX module, support 1000BASE-T optical module |
SFP+ slot | - | |
GE optical BYPASS link | 2 link,4*1Gbase-SX multimode interface | |
Deploy mode |
Number of link protection links | Maximum support for 2 GE optical BYPASS link |
Monitor | Maximum support 2 GE optical / electrical link monitor | |
Index parameter | Multi-mode insertion loss | 1.1dB to 1.6dB |
Multimode emission optical power | -9dB to -4dB | |
Multimode receive optical power | ≥-18dB | |
Multimode operating wavelength | 850nm | |
Multimode transmission distance | 300M | |
Single mode short insertion loss | 1.1dB to 1.6dB | |
Single mode short distance emission optical power | -9dB to -3dB | |
Single mode short distance receiving optical power | ≥-24dB | |
Single mode short working wavelength | 1310nm | |
Single mode short distance transmission distance | 20KM | |
Single mode mid - range insertion loss | 1.1dB to 1.6dB | |
Single mode mid - range emitting optical power | -5dB to 0dB | |
Single mode mid - range received optical power | ≥-25dB | |
Single mode midpoint working wavelength | 1310nm | |
Single mode distance transmission distance | 40KM | |
Single mode long distance insertion loss | 1.1dB to 1.6dB | |
Single mode long distance emission optical power | 0dB to 5dB | |
Single mode long distance receiving optical power | ≥-26dB | |
Single mode long distance working wavelength | 1550nm | |
Single mode long distance transmission distance | 80KM | |
Functional performance | Total number of interfaces | 8 |
Line speed processing capacity | 8Gbps | |
Cross - link protection based on IP / protocol / port quintuple specific traffic | Support | |
Based on the total flow of the series protection | Support | |
Multi - channel load balancing function | Support | |
Custom heartbeat message function | Support | |
Ethernet encapsulation support | Support | |
BYPASS switching function | Support | |
Bypass switch without flash | Support | |
CONSOLE network management | Support | |
IP/WEB network management | Support | |
SNMP V1/V2C network management | Support | |
TELNET/SSH network management | Support | |
SYSLOG protocol | Support | |
User authentication function | Based on user name and password authentication | |
Electric | Rated supply voltage | AC-220V/DC-48V【Optional】 |
Rated power frequency | 50HZ | |
Rated input current | AC-3A / DC-10A | |
Rated Power | 40W | |
Environment | Working Temperature | 0-50℃ |
Storage temperature | -20-70℃ | |
Working humidity | 10%-95%,No condensation | |
User configuration | console configuration | RS232 interface,9600,8,N,1 |
Outside network management interface | 1*10/100/1000M Ethernet interface | |
Password authentication | Support | |
Dimension | Chassis dimension (U) | 1U 485mm*44.5mm*350mm |