Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond

Product Details

Place of Origin: China

Brand Name: NetTAP®

Certification: CCC, CE, RoHS

Model Number: NT-FBYP-L1G

Payment & Shipping Terms

Minimum Order Quantity: 1 SET

Price: Can Discuss

Packaging Details: Outer Carton plus Inner Foam

Delivery Time: 1-3 Working Days

Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability: 100 sets per month

Get Best Price
Contact Now
Specifications
High Light:

anti ddos protector

Inline Bypass:
Deploy With, Anti-DDoS
BYPASS Detection:
Intelligent Heartbeat Technology
Network Monitor:
Monitoring Tools Depend On Heartbeat Package
Reliable Data Access:
Up/down Link Heartbeat Package Respond
Applications::
Data Center Physical Connection Protection
Heartbeat Packet Detection:
VLAN Tag, L3 And L4 Custom Message
Inline Bypass:
Deploy With, Anti-DDoS
BYPASS Detection:
Intelligent Heartbeat Technology
Network Monitor:
Monitoring Tools Depend On Heartbeat Package
Reliable Data Access:
Up/down Link Heartbeat Package Respond
Applications::
Data Center Physical Connection Protection
Heartbeat Packet Detection:
VLAN Tag, L3 And L4 Custom Message
Description
Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond

Inline Bypass Network TAP Detect Heartbeat Message Respond for Anti DDos Protector
 
1. Anti DDos Protector Bypass TAP Intelligent Heartbeat Message Detection Technology

 

Define Heartbeat Messages

The heartbeat packets of the NetTAP® policy traction protector default to Ethernet Layer 2 frames. When deploying transparent Layer 2 bridging mode (such as IPS / FW), Layer 2 Ethernet frames are normally forwarded,blocked or discarded. At the same time, NetTAP® policy traction protector also supports custom heartbeat message format to meet the situation that some special serial security devices can not normally forward ordinary Layer 2 Ethernet frames.

The NetTAP® Policy Traction Protector also supports heartbeat packet detection based on VLAN tag, Layer 3 and Layer 4 custom message types. Based on this mechanism, the user can implement a service safety test function of the connection safety device to make it more effective to ensure that the corresponding security services work properly.

NetTAP® "Strategic Traffic Traction Protector" can also support the monitor to send different heartbeat packets in both directions. For example, TCP and UDP type heartbeat packets are customized on the "Strategy Traffic Traction Protector", according to the particularity of the serial device. You can configure the sending of TCP heartbeat packets on the uplink monitor A port and the sending of UDP heartbeat packets on the downlink monitor B port to accommodate the message forwarding mechanism of the serial security device. This function can more effectively guarantee the string. Connect the safety equipment to normal operation.


2. Intelligent Anti DDos Protector Application Solution​
Based on the dynamic strategy of traffic traction security detection protection
"Bypass Switch" Another advanced application scenario is based on the dynamic strategy of traffic traction security detection protection applications, the deployment of the way as shown below:
 Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond 0

Take the "anti-DDoS attack protection and detection" security testing equipment, for example, through the front-end deployment of "bypass switch" and then anti-DDOS protection equipment and then connected to the "bypass switch", in the usual " Traction protector "to the full amount of traffic wire-speed forwarding at the same time the flow mirror output to the" anti-DDOS attack protection device ", once detected for a server IP (or IP network segment) after the attack," anti-DDOS attack protection device " will generate the target traffic flow matching rules and send them to the "bypass switch" through the dynamic policy delivery interface. The "bypass switch" can update the "traffic traction dynamic" after receiving the dynamic policy rules Rule pool "and immediately" rule hit the attack server traffic "traction to the" anti-DDoS attack protection and detection "equipment for processing, to be effective after the attack flow and then re-injected into the network.

The application scheme based on the "bypass switch" is easier to implement than the traditional BGP route injection or other traffic traction scheme, and the environment is less dependent on the network and the reliability is higher.

"Bypass Switch" has the following characteristics to support dynamic policy security detection protection:

1,"bypass switch" to provide outside the rules based on WEBSERIVCE interface, easy integration with third-party security devices.

2,"bypass switch" based on the hardware pure ASIC chip forwarding up to 10Gbps wire-speed packets without blocking switch forwarding, and "traffic traction dynamic rule library" regardless of the number.

 

3,"policy flow traction protector" built-in professional BYPASS function, even if the protector itself failure, can also bypass the original serial link immediately, does not affect the original link of normal communication.

Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond 1
 
3. Anti DDos Protector Bypass TAP Technical Specifications

Product model Specifications
NT-FBYP-L1X-SR 1U chassis, 1*10GE multimode optical protection link
NT-FBYP-L1X-LR 1U chassis, 1*10GE single-mode optical protection link
NT-FBYP-L1G-SX 1U chassis, 1*GE multi-mode optical protection link
NT-FBYP-L1G-LX 1U chassis, 1*GE single mode optical protection link
NT-CBYP-L1G 1U chassis, 1*GE electrical protection link
NT-CBYP-L2G 1U chassis, 2*GE electrical protection link
NT-FBYP-L2G-SX5 1U chassis, 2*GE multi-mode optical protection link
NT-FBYP-L2G-LX 1U chassis, 2*GE single-mode optical protection link
NT-FCBYP-L4XG-SR 1U chassis, 2*GE electrical protection link, 1*GE multi-mode optical protection link, 1*10GE multimode optical protection link
NT-FCBYP-L4XG-LR 1U chassis, 2*GE electrical protection link, 1*GE single mode optical protection link, 1*10GE single mode optical protection link
 

2*GE Optical BYPASS Links(NT-FBYP-L2G)
Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond 2

 

Product Model NT-FBYP-L2G
Interface form SFP slot 4 * SFP slot, support 1000BASE-LX / SX module, support 1000BASE-T optical module
SFP+ slot -
GE optical BYPASS link 2 link,4*1Gbase-SX multimode interface

 

Deploy

mode

Number of link protection links Maximum support for 2 GE optical BYPASS link
Monitor Maximum support 2 GE optical / electrical link monitor
Index parameter Multi-mode insertion loss 1.1dB to 1.6dB
Multimode emission optical power -9dB to -4dB
Multimode receive optical power ≥-18dB
Multimode operating wavelength 850nm
Multimode transmission distance 300M
Single mode short insertion loss 1.1dB to 1.6dB
Single mode short distance emission optical power -9dB to -3dB
Single mode short distance receiving optical power ≥-24dB
Single mode short working wavelength 1310nm
Single mode short distance transmission distance 20KM
Single mode mid - range insertion loss 1.1dB to 1.6dB
Single mode mid - range emitting optical power -5dB to 0dB
Single mode mid - range received optical power ≥-25dB
Single mode midpoint working wavelength 1310nm
Single mode distance transmission distance 40KM
Single mode long distance insertion loss 1.1dB to 1.6dB
Single mode long distance emission optical power 0dB to 5dB
Single mode long distance receiving optical power ≥-26dB
Single mode long distance working wavelength 1550nm
Single mode long distance transmission distance 80KM
Functional performance Total number of interfaces 8
Line speed processing capacity 8Gbps
Cross - link protection based on IP / protocol / port quintuple specific traffic Support
Based on the total flow of the series protection Support
Multi - channel load balancing function Support
Custom heartbeat message function Support
Ethernet encapsulation support Support
BYPASS switching function Support
Bypass switch without flash Support
CONSOLE network management Support
IP/WEB network management Support
SNMP V1/V2C network management Support
TELNET/SSH network management Support
SYSLOG protocol Support
User authentication function Based on user name and password authentication
Electric Rated supply voltage AC-220V/DC-48V【Optional】
Rated power frequency 50HZ
Rated input current AC-3A / DC-10A
Rated Power 40W
Environment Working Temperature 0-50℃
Storage temperature -20-70℃
Working humidity 10%-95%,No condensation
User configuration console configuration RS232 interface,9600,8,N,1
Outside network management interface 1*10/100/1000M Ethernet interface
Password authentication Support
Dimension Chassis dimension (U) 1U 485mm*44.5mm*350mm
 
Send your inquiry