Ethernet Network Tap Bypass Switch Centralized NetFlow And IPFIX​ With Optical Protection Link

Product Details

Place of Origin: China

Brand Name: NetTAP®

Certification: CCC, CE, RoHS

Model Number: NT-FBYP-L1X

Payment & Shipping Terms

Minimum Order Quantity: 1 SET

Price: Can Discuss

Packaging Details: Outer Carton plus Inner Foam

Delivery Time: 1-3 Working Days

Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability: 100 sets per month

Get Best Price
Contact Now
Specifications
High Light:

ethernet bypass switch

Interface Form:
2*SFP+ 10G Singlemode Optical Protection Link
BYPASS Switching:
Without Flash
Network Monitor:
Monitoring Tools Depend On Heartbeat Package
Transmission Distance:
300M/10/40/80Km
Applications::
Data Center Of Telecom, Broadcasting, Government, Finance, Energy, Power, Petroleum, Hospital, School, Enterprise And Other Industries
Customized Heartbeat Message:
Supported
Interface Form:
2*SFP+ 10G Singlemode Optical Protection Link
BYPASS Switching:
Without Flash
Network Monitor:
Monitoring Tools Depend On Heartbeat Package
Transmission Distance:
300M/10/40/80Km
Applications::
Data Center Of Telecom, Broadcasting, Government, Finance, Energy, Power, Petroleum, Hospital, School, Enterprise And Other Industries
Customized Heartbeat Message:
Supported
Description
Ethernet Network Tap Bypass Switch Centralized NetFlow And IPFIX​ With Optical Protection Link

Network TAP Bypass Switch Centralized NetFlow and IPFIX​ with Single Mode Optical Protection Link

 

1. Overviews

With the rapid development of the Internet, the threat of network information security is becoming more and more serious, so a variety of information security protection applications are used more and more widely. Whether it is traditional access control equipment (firewall) or a new type of more advanced protection means such as intrusion prevention system (IPS),Unified threat management platform (UTM), Anti-denial service attack system (Anti-DDoS), Anti-spam Gateway, Unified DPI Traffic Identification and Control System, and many security devices are deployed in series in the network key nodes, the implementation of the corresponding data security policy to identify and deal with legal / illegal traffic. At the same time, however, the computer network will generate a large network delay or even network disruption in the case of fail over, maintenance, upgrade, equipment replacement and so on in a highly reliable production network application environment, users cannot stand it.

NetTAP® bypass switch manual is researched and developed by Chengdu Shuwei Communication Technology Co., Ltd, which can be used for flexible deployment of various types of serial security equipment while providing high network reliability.

By deploying NetTAP® Smart Bypass Protector:

- Users can flexibly install/uninstall security equipment and will not affect the current network and interrupt;

- NetTAP® bypass switch manual with intelligent health detection function to real-time monitoring of the normal working state of the serial security device, once the serial security device work exception, the protection will automatically bypass to maintain the normal network communication;
- Selective traffic protection technology can be used to deploy specific traffic cleaning security equipment, encryption technology based on the audit equipment. Effectively carry out the serial access protection for the specific traffic type, unloading the flow handling pressure of the series device;

- Load Balanced Traffic Protection technology can be used for clustered deployment of secure serial devices to meet the need for serial security in high-bandwidth environments.

 

2. Intelligent Bypass Swtich Application Solution​

“Specflow” Policy Flow Traction Series Protection

 

Ethernet Network Tap Bypass Switch Centralized NetFlow And IPFIX​ With Optical Protection Link 0

 

As shown above, when the security network device only needs to deal with the specific traffic in series security protection, through the NetTAP® "bypass switch" traffic per-processing function, through the traffic screening strategy to connect the security device " Concerned "traffic is sent back directly to the network link, and the" concerned traffic section "is traction to the in-line safety device to perform safety checks. This will not only maintain the normal application of the safety detection function of the safety device, but also reduce the inefficient flow of the safety equipment to deal with the pressure; at the same time, the "policy flow traction protector" can detect the working condition of the safety device in real time. The safety device works abnormally bypasses the data traffic directly to avoid disruption of network service.

The NetTAP® Traffic Traction Protector can identify traffic based on the L2-L4 layer header identifier, such as VLAN tag,source / destination MAC address, source IP address, IP packet type, transport layer protocol port, protocol header key tag, and so on. A variety of matching conditions flexible combination can be defined flexibly to define the specific traffic types that are of interest to a particular security device and can be widely used for the deployment of special security auditing devices (RDP, SSH, database auditing, etc.).

 

3. Bypass Switch Bypass TAP Technical Characteristics

LinkSafeSwitch Technology

 

NetTAP® Network TAP Bypass Switch Policy Traction Protector can be customized heartbeat interval and the maximum number of retries, to detect and determine the fault status of the serial security device in order to achieve the protection of the fast bypass switch. At the same time, NetTAP® policy traffic traction protector unique link switching technology can ensure that the implementation of the bypass switch when the main link state without any impact. This technique will ensure that the bypass switch is more secure and will not cause the Layer 2 / Layer 3 topology protocol of the protected link to recalculate and converge.

 

4. Bypass Switch Bypass TAP Technical Specifications

Product model Specifications
NT-FBYP-L1X-SR 1U chassis, 1*10GE multimode optical protection link
NT-FBYP-L1X-LR 1U chassis, 1*10GE single-mode optical protection link
NT-FBYP-L1G-SX 1U chassis, 1*GE multi-mode optical protection link
NT-FBYP-L1G-LX 1U chassis, 1*GE single mode optical protection link
NT-CBYP-L1G 1U chassis, 1*GE electrical protection link
NT-CBYP-L2G 1U chassis, 2*GE electrical protection link
NT-FBYP-L2G-SX5 1U chassis, 2*GE multi-mode optical protection link
NT-FBYP-L2G-LX 1U chassis, 2*GE single-mode optical protection link
NT-FCBYP-L4XG-SR 1U chassis, 2*GE electrical protection link, 1*GE multi-mode optical protection link, 1*10GE multimode optical protection link
NT-FCBYP-L4XG-LR 1U chassis, 2*GE electrical protection link, 1*GE single mode optical protection link, 1*10GE single mode optical protection link
 

1*10GE Optical BYPASS link(NT-FBYP-L1X-LR)

Ethernet Network Tap Bypass Switch Centralized NetFlow And IPFIX​ With Optical Protection Link 1

 

 

Product Model NT-FBYP-L1X-LR Optical Bypass Network TAP
Interface form SFP + slot 2 * SFP + interface, support 10 Gigabit optical / electrical modules
10G optical Bypass link 1 link, 2 * 10Gbase-SR multimode interface

 

Deploy mode

Number of link protection links Maximum support for a 10GE BYPASS link
Monitor 1*10GE monitoring link (2 * SFP + slot), supported 10GBASE-LR/SR
Index parameter Multi-mode insertion loss 1.1dB to 1.6dB
Multimode emission optical power -7.3dB to 1dB
Multimode receive optical power ≥-12dB
Multimode operating wavelength 850nm
Multimode transmission distance 300M
Single mode short insertion loss 1.1dB to 1.6dB
Single mode short distance emission optical power -6dB to 0.5dB
Single mode short distance receiving optical power ≥-14dB
Single mode short working wavelength 1310nm
Single mode short distance transmission distance 10KM
Single mode mid - range insertion loss 1.1dB to 1.6dB
Single mode mid - range emitting optical power -1dB to 3dB
Single mode mid - range received optical power ≥-18dB
Single mode midpoint working wavelength 1550nm
Single mode distance transmission distance 40KM
Single mode long distance insertion loss 1.1dB to 1.6dB
Single mode long distance emission optical power 0dB to 4dB
Single mode long distance receiving optical power ≥-24dB
Single mode long distance working wavelength 1550nm
Single mode long distance transmission distance 80KM
Functional performance Total number of interfaces 4
Line speed processing capacity 40Gbps
Cross - link protection based on IP / protocol / port quintuple specific traffic Support
Based on the total flow of the series protection Support
Multi - channel load balancing function -
Custom heartbeat message function Support
Ethernet encapsulation support Support
BYPASS switching function Support
Bypass switch without flash Support
CONSOLE network management Support
IP/WEB network management Support
SNMP V1/V2C network management Support
TELNET/SSH network management Support
SYSLOG protocol Support
User authentication function Based on user name and password authentication
Electric Rated supply voltage AC-220V/DC-48V【Optional】
Rated power frequency 50HZ
Rated input current AC-3A / DC-10A
Rated Power 45W
Environment Working Temperature 0-50℃
Storage temperature -20-70℃
Working humidity 10%-95%,No condensation
User configuration console configuration RS232 interface,9600,8,N,1
Outside network management interface 1*10/100/1000M Ethernet interface
Password authentication Support
Dimension Chassis dimension(U)

1U 485mm*44.5mm*350mm

 

Ethernet Network Tap Bypass Switch Centralized NetFlow And IPFIX​ With Optical Protection Link 2NT-MBYP-CHS Bypass Switch.pdf 